WEB 2.0 - IBM turns server sideways for Web 2.0 build-out

By James Niccolai , IDG News Service , 04/23/2008

IBM has designed a new type of rack-mount server specifically for companies running heavily trafficked "Web 2.0" sites such as Facebook and MySpace, the company announced Wednesday.

Called the iDataPlex, the server is designed to compete with the unbranded "white-box" PCs that online companies link together by the thousand to run busy Web sites. IBM said its new server, which runs Linux and is based on Intel's quad-core Xeon processors, consumes 40 percent less power and packs more computing punch than a typical rack-mount system. The energy savings come largely from a new design that requires less power for cooling, IBM said.

Rack servers are the slender machines shaped like an oblong pizza box and stacked on top of each other in server chassis. The servers come in standard heights -- 1u or 2u -- but their depth, or how far back they reach into the chassis, has been expanding as vendors try to cram more hardware components inside.

That has created a problem, according to IBM. Cooling systems blow air over the servers from back to front, and as the servers become deeper it takes more energy to power the fans that cool them. "The power used by the fan is proportional to the cube of the fan speed, so if you want to double the fan speed you have to use eight times the power," said Gregg McKnight, CTO of IBM's modular systems group.

IBM's answer is to rotate the server horizontally through 90 degrees, producing a server that is wider than usual but only 15 inches deep, compared to about 25 inches for a typical rack server. "That allowed us to run fans at a much lower velocity, and therefore save about 67 percent on the fan energy alone," he said.

IBM also pushed two racks together, creating a single wide rack that holds 84 iDataPlex servers. That allowed it to share three power whips between the servers, while two separate racks would normally use four. Power whips, the moveable outlets attached to power cables, cost $1,500 to $2,000 per month to maintain, McKnight said.

The broad surface area at the back also allowed IBM to design an optional water-cooled rear-door heat exchanger, which IBM said extracts all of the heat from the system, so it doesn't contribute to datacenter warming.

The trade-off for sharing power cables is a less fault-tolerant system, but the software used to run busy Web sites is usually designed to fail over quickly to another server. "We interviewed Web 2.0 companies and they told us unanimously that they are designing their applications to tolerate server failures. So because it's more economical and more energy efficient, it's an attractive trade-off for them," McKnight said.

Partner Content

Explore the Ultrium Edge

The powerful tape technology can address data security with tape encryption as well as long term data protection.

Find out more

Disk and Tape Square Off

Discover what disk and tape really cost -- and which solution provides lower total cost of ownership and optimizes energy use for your organization

Download the White Paper

Don't Fall For The Myths

The Clipper Group explores the truth behind the myths of tape, digging into the misconceptions in the disk vs. tape debate.

Download the White Paper

Will You Add Tape Too?

Over two thirds of disk-only users look to add tape back into storage infrastructure according to recent survey.

Download Survey Information

Comment
Login
Forgot your account info?
Add comment
Anonymous comments subject to moderator approval. Register here for member benefits.
Have a NetworkWorld account? Log in here. Register now for a free account.

Videos

rssRss Feed
Save The Date!
What They Are Saying

Investment of a Technology should be 'held off' because there hasn't been enough investment in it yet? Is...- Anonymous

Join the Discussion