Data centers are the biggest consumers of utility power in most large companies. Power needs range from 1 kilowatt per rack to more than 25 kilowatts per rack for dense blade servers. With rising prices in the energy markets, the electricity bill for your data centers could take a big bite out of your budgets. Increasing energy efficiency in the data center is not only an environmentally friendly strategy, but also a smart way to cut costs.
One way to increase energy efficiency is to run power and cooling units as close as possible to their maximum capacity, increasing the operational efficiency. But in many data centers, the exact opposite is the case. Data centers are designed with redundant cooling and power configurations - for every kilowatt of power demand, two kilowatts are provided on redundant circuits.
As redundancy increases, utilization decreases. In a fully redundant system, utilization cannot exceed 25%. At this range, both power and cooling systems exhibit their lowest levels of efficiency. For example, if a power system loses up to 5% of its total capacity to heat regardless of utilization (the static loss), at 25% utilization you are losing a fifth of your input power.
Data center managers who want to control their cooling and power costs are caught in a potential dilemma: high redundancy means worst-case efficiency. At the same time, provisioning cooling and power is extremely disruptive. In most cases, you have to shut down your data center to re-engineer your power or cooling. So many data center managers invest in cooling and heating based on the maximum projected demand. That can result in very low utilization - you’ve built a data center for the future and your electricity bills are also futuristically huge.
Here are some steps that can lead to a cleaner data center:
* Focus high-power and high-density cooling systems on a part of your data center rather than the whole data center. Essentially, you can build a Tier-II data center with a section dedicated to high-density computing and designed to Tier-IV standards.
* Enclosed hot aisles can concentrate heat dissipated from blade racks. That way you can apply your cooling as close as possible to the heat source. Concentrating heat is counter-intuitive, but it greatly increases the efficiency of cooling systems. A few degrees Fahrenheit difference can double your effective cooling capacity.
www.google-alba.ch faqja e intrnetit me e mira ku mund te gjeni gjithcka vizitojeni dhe do te mbeteni...- Anonymous
Partner Content
Explore the Ultrium Edge
The powerful tape technology can address data security with tape encryption as well as long term data protection.
Find out more
Disk and Tape Square Off
Discover what disk and tape really cost -- and which solution provides lower total cost of ownership and optimizes energy use for your organization
Download the White Paper
Don't Fall For The Myths
The Clipper Group explores the truth behind the myths of tape, digging into the misconceptions in the disk vs. tape debate.
Download the White Paper
Will You Add Tape Too?
Over two thirds of disk-only users look to add tape back into storage infrastructure according to recent survey.
Download Survey Information
Comment