Data centers are often designed (or overdesigned) to handle the highest load that might come their way, which really doesn't jibe with the green ideal.
Part of the problem is the fickle nature of CPU and chipset power saving techniques we tested (see main story) may not translate into linear power savings because of where the power company measures consumption for billing. Uninterruptible power supplies (UPSs) electrically work like large capacitors in that they deliver power in a linear fashion, backfilling electrons smoothly as they are consumed. CPU conservation efforts designed to save server power aren't realized where power is metered by the power company in the same linear fashion that they are served up to the UPS. The UPS generally stores enough energy for all items plugged into it plus extra capacity needed in case of a service interruption from the power company. This means the draw of the UPS on the power company's transformers isn't a direct reflection of the power that in-line devices are using.
Secondly, the process of cooling CPUs and other server components is often geared toward the highest cooling requirement. Network operations center (NOC) temperatures are often measured in five minute (or longer) periodic samples, and cooling is adjusted according to the rise and fall of ambient temperature (or the average of either single or multiple area sensors). Even though a single server's power consumption is likely to vary widely (in our tests, as much as 17%), cooling must be available for the maximum heat output mandated by the server's requirements.
As servers in racks may also be affected by other server temperature rises and chills within the server or 'temperature zone', servers tend to average each other's ambient temperature through active cooling (fans and heat dissipation design). This makes it more difficult still to react to the fast, tiny changes in CPU and chipset temperatures as they wake-up and sleep for just milliseconds at a time.
The bottom line is NOCs don't react to power consumption and heat dissipation in direct correlation to a server's needs, and design practices tend to sway settings to the highest consumption/chilling needed, rather than reacting in complete harmony with rapid power consumption characteristics dictated by green principles.
Partner Content
Explore the Ultrium Edge
The powerful tape technology can address data security with tape encryption as well as long term data protection.
Find Out More
Disk and Tape Square Off
Discover what disk and tape really cost and which solution provides lower total cost of ownership and optimizes energy use for your organization
Download this White Paper
Don't Fall for the Myths
The Clipper Group explores the truth behind the myths of tape, digging into the misconceptions in the disk vs. tape debate.
Review this information
information examination
An examination of information security issues, methods and securing data with LTO-4 tape drive encryption
Read this analysis
Comment