Danger in the new data center

Bob Doherty, a leader in the Data Center Institute think tank, examines the health and well-being of the new data center.
By Beth Schultz , Network World , 10/25/2004
  • Share/Email
  • Tweet This
  • Comment
  • Print

Planning the new  data center  means more than plotting out server consolidation and virtualization. It also means knowing the effect these have on overall data center design. Bob Doherty, a 30-year IT veteran, studies such issues for the Data Center Institute, a think tank run by AFCOM, an association for data center professionals. In an interview with Signature Series Editor Beth Schultz, Doherty describes what he calls the new data center's "physiology" - and explains why conditions might deteriorate quickly.

What do you mean by 'data center physiology'?

Because the data center is evolving so fast, with ever-increasing demands for uptime and the introduction of new technologies such as blade servers and grid computing, I liken the data center to a living, breathing and growing entity. So when I talk about physiology, I mean those ingredients - the nutrients - that give the data center life. That energy source that fosters healthy performance. Unfortunately, I see all too many data centers in decline - they are not healthy.

What is causing this illness - new server consolidation technologies and the like?

For the past 25 years, data center managers have been able to host most any type of technology within the walls of their data centers. We think and calculate in increments of 2-foot-square blocks, as this is the size of the data center's raised floor panel. Equipment will usually conform to this mental grid we see as we plan the addition of more equipment and technology. Server consolidation has allowed us to free up valuable floor space in the data center. Glen Goss, of GJ Associates in Stow, Mass., hosted a conference a few months back at which I heard a report on the cost of a Tier-1 data center to be a staggering $1,060 per square foot. So consolidation looks to be a real benefit for us. That whopping $1,060 per square foot sounds like a premium price to me. So, yes, miniaturization is a good thing - at first glance.

Just at first glance? Why?

Can you remember not so many years ago running applications on an Intel 486? Conservatively, that hardware required 10U of space in a 19-inch computer rack with power consumption at about 6 amps for each server. So in a 42U-high, 19-inch rack we were able to host four computers. Power consumption was around 2kW per rack. We also are using an area half the size of the space allotted to our computer equipment for service and utilities to support the data center's infrastructure needs. Miniaturization looked like a dream come true because we started putting 10 servers in one rack - then 15. Things were looking good until we realized we were not able to dissipate the heat being generated in a rack with 15 or more servers.

How about all those cables we have in one rack now? It's next to impossible to trace any of the cables, and we are getting hamstrung when trying to service equipment in these racks. But perseverance and tweaking things for a couple of years lowered our temperatures. Variable speed computer fans helped, and then there is acceptance of the hot aisle, cold aisle concept. Cable management was not as successful - but we did make some headway. Yet the physical size of servers continues to evolve dramatically. My research suggests 48 blade servers will fit into one 19-inch computer rack.

  • Share/Email
  • Tweet This
  • Comment
  • Print

Partner Content

Gartner 2009 Magic Quadrant for Job Scheduling

Gartner has positioned BMC CONTROL-M in the Leaders Quadrant of their "2009 Magic Quadrant for Job Scheduling." The report assesses the ability to execute and completeness of vision of key vendors in the marketplace. Read a full copy today, courtesy of BMC Software.

Download whitepaper

Dell's SMART Approach to Workload Automation

Read a compelling case study by EMA, Inc. to learn how Dell uses BMC CONTROL-M to cut cost and increase productivity with workload automation.

Download whitepaper

Workload Automation Cost Savings 2 Minute Video

A major computer manufacturer uses BMC CONTROL-M and just four people to schedule and run over 85,000 jobs every month. By switching to BMC CONTROL-M, they more than quadrupled the workload without adding a single staff member.  See how in this 2-minute video overview.

Go to video

Comment
Login
Forgot your account info?
Add comment
Anonymous comments subject to approval. Register here for member benefits.
Have a NetworkWorld account? Log in here. Register now for a free account.

Videos

rssRss Feed